Restaurant Energy Analysis
| Energy Audit Checklist |
|
| Heating, Ventilation and Air Conditioning (HVAC) – Operation | |
| Winter recommended temperature, 68°F. | |
| Winter recommended setback temperature, 50°F. | |
| Summer recommended temperature setting, 75°F with 55% relative humidity. | |
| Monitor make up air ventilation (15 cfm/person required non-smoking area, 60 cfm/per person smoking area). | |
| Avoid heating and cooling at the same time. | |
| Use timers for start/stop cycles. | |
| Utilize programmable thermostats to maximize comfort and efficiency. | |
| Heating, Ventilation and Air Conditioning (HVAC) – Maintenance | |
| Replace furnace filters on a monthly or bi-monthly schedule. | |
| Allow free airflow to and from registers. | |
| Insulate hot water heater(s) and pipes, and ductwork located in unconditioned areas. | |
| Cover and lock thermostats and ventilation controls to prevent unauthorized adjustments. | |
| Check for unusual noise, vibration and decrease in performance of compressors/motors. | |
| Seal ductwork leaks. | |
| Inspect/clean condenser coils. | |
| Clean and disinfect condensate drain pans. | |
| Set up monthly/bi-monthly maintenance contract. | |
| Heating, Ventilation and Air Conditioning (HVAC) – Procedures | |
| Minimize heating and cooling in unoccupied, low-traffic areas or when building is not in use. | |
| Adjust building temperature by season; lower in winter and higher in summer. | |
| Utilize ceiling fans whenever possible. | |
| Close doors to outside and unconditioned areas. | |
| Use exhaust ventilation only when required. | |
| Seal ductwork leaks. | |
| If fossil fuels are present, test operation of carbon monoxide (CO) detectors monthly. | |
| Refrigeration – Operation | |
| Keep cold air supply and return registers clean and clear of product. | |
| Maintain minimum recommeded refrigeration temperature for produce. | |
| Optimal refrigeration efficiency is achieved with ambient air relative humidity levels between 40-55%. | |
| Identify feasibility of venting or recovering the rejected heat off the refrigeration condensers. | |
| Refrigeration – Maintenance | |
| Check for unusual noise, vibration and decrease in performance of compressors/motors. | |
| Clean refrigeration coils regularly. | |
| Replace worn and/or leaky door seals. | |
| Verify operation and efficiency of defrost timers and moisture sensors to ensure optimal performance. | |
| Clean and disinfect condensate drain pans. | |
| Monthly/bi-monthly maintenance contract. | |
| Refrigeration – Procedures | |
| Follow manufacturer’s recommendations for shelf position and size. | |
| Keep upright display case doors shut. | |
| Rotate stock regularly. | |
| Do not let refrigerated items sit and warm-up during delivery and/or restocking. | |
| Turn off refrigeration unit when not in use. | |
| Lighting – Operation | |
| Use automated lighting controls. | |
| Utilize photocells for all-night outdoor lighting. | |
| Use timers in parking lots and restricted-access areas. | |
| Utilize dimming controls to take advantage of daylighting. | |
| Use motion sensors for low-traffic areas. | |
| Always de-energize ballasts that are not in use. | |
| Verify recommended illumination levels. | |
| Reduce lighting to minimum acceptable level for safety/security in: hallways, restrooms, storeroom and coolers. | |
| Lighting – Maintenance | |
| Clean lamps and fixtures for maximum illumination. | |
| Repair/replace broken fixtures. | |
| Replace non-working lamps with the lowest wattage available while maintaining lumen output. | |
| Develop and implement a lamp upgrade program to energy efficient lighting (T-8, compact fluorescent, etc.). | |
| Add reflectors to existing lighting. | |
| Label panels and switches so lighting can be monitored and controls can be accessed. | |
| Lighting – Procedures | |
| Turn off lights not being used. | |
| Use task lighting in place of area lighting where possible. | |
| Open drapes/blinds and use natural lighting when possible. | |
| Use decorative lighting and electrical signs only during high-traffic hours. | |
| Kitchen – Operation | |
| Preheat ovens only when necessary and set to minimum preheat temperature. | |
| Turn off or reduce temperature of fryers during low demand periods. | |
| Slow down or turn off exhaust hoods during slow food preparation periods. | |
| Kitchen – Maintenance | |
| Make sure oven doors close and seal properly. | |
| Clean ovens regularly. | |
| Verify thermostat accuracy and recalibrate if necessary. | |
| Keep gas appliance’s orifices free of debris. | |
| Evaluate feasibility of a thermostatically controlled exhaust fan in hot areas of kitchen. | |
| Kitchen – Procedures | |
| Bake during off-peak cooling periods when possible. | |
| Bake foods needing lowest temperature first. | |
| Bake in large volumes. | |
| Provide adequate space between pans and oven walls. | |
| Load and unload ovens quickly to avoid heat loss. | |
| Turn off oven shortly before baking time is complete and keep door closed to maintain temperature. | |
| Building Envelope | |
| Check and verify insulation levels. | |
| Fill in outside air leaks with a low expanding foam. | |
| Replace cracked or missing window and door caulking. | |
| Install solar film or blinds for windows with east, west or south exposure. | |
| Replace cracked or missing weather-stripping. | |
Contact your local NPPD Energy Efficiency Consultant for additional information or to identify energy conservation opportunities in greater detail.